Every batch.
Every lot.
Independently confirmed.
Arcovex Verified connects every physical vial — its lot number, QR code, and expiration date — to a traceable chain of third-party analytical results. Researchers will be able to verify any lot independently using the verification ID printed on the label.
The live lookup portal is in development. Once available, entering a verification ID here will return that lot's COA, identity, and endotoxin results directly. Until then, request lot-specific documentation via Research Inquiry.
How Arcovex Verified Works
01
Synthesis &
Manufacture
Contracted synthesis partner. Internal QC hold pending third-party results.
02
Sample
Submission
Representative sample submitted to accredited independent laboratory.
03
Independent
Lab Testing
HPLC purity, LC-MS identity, LAL endotoxin, and SDS documentation.
04
Results Review
& Release
Lots failing purity threshold are rejected. Passing lots receive a verification ID.
05
QR Index &
Label Print
Lot ID, COA, and expiration linked via QR to the verification record.
Arcovex Biotech
BPC-157
5 MG / vial
CompoundBPC-157
LotLOT-2025-B157-014
HPLC Purity>99.1% ✓
LC-MSIdentity confirmed ✓
Endotoxin<1.0 EU/mg ✓
COARequest via inquiry
The panel above illustrates the structure of a verification record once the portal is live. Field values shown are representative, not a live lookup result.
Sample Verified Lot Records
LOT-2025-B157-014
BPC-157
5 MG · Lyophilized
HPLC>99.1%
LC-MSConfirmed
Endotoxin<1.0 EU/mg
LOT-2025-RET-022
Retatrutide
10 MG · Lyophilized
HPLC>98.5%
LC-MSConfirmed
Endotoxin<1.0 EU/mg
LOT-2025-NAD-009
NAD+
1000 MG · Lyophilized
HPLC>99.0%
LC-MSConfirmed
EndotoxinNot applicable
LOT-2025-TRZ-018
Tirzepatide
5 MG · Lyophilized
HPLC>98.9%
LC-MSConfirmed
Endotoxin<1.0 EU/mg
Testing Standards Reference
Method
Full Name
What It Confirms
Status
HPLC
High-Performance Liquid Chromatography
Purity quantification. Identifies co-eluting impurities and confirms compound fraction by area percentage.
Applied per profile
LC-MS
Liquid Chromatography–Mass Spectrometry
Molecular identity verification. Confirms exact mass and fragmentation pattern against reference standard.
Applied per profile
LAL
Limulus Amebocyte Lysate (Endotoxin)
Bacterial endotoxin quantification. Result reported as EU/mg against internal release threshold.
Applied per profile
SDS
Safety Data Sheet (GHS-compliant)
Handling, storage, disposal, and emergency procedure documentation per GHS classification.
Applied per profile
"Applied per profile" reflects that not every test method applies to every compound class — see each product's Testing Profile section for the specific methods used on that compound.